Technical Annual Status Report (Stage I) of CLRTAP and NECD Inventory Review for Portugal

Generated by CEIP: 22 th May 2017

This status report was prepared by the EMEP Centre on Emission Inventories and Projections (CEIP) and European Topic Centre on Air and Climate Change (ETC/ACC). The Status Report provides information based on the initial checks of the CLRTAP and NECD inventories submitted in accordance with the reporting requirements of the UNECE Convention on Long-Range Transboundary Air Pollution (CLRTAP) and its protocols, and for EU Member States the Directive 2001/81/EC of the European Parliament and of the Council on national emission ceilings for certain atmospheric pollutants (NECD).


Review Process

The technical review of national inventories involves the checking and assessment of national data submissions with a view to improving the quality of emission data and associated information.

The annual review process is carried out in three stages in accordance with the review guidelines developed by the Task Force on Emission Inventories and Projections (TFEIP) and as agreed upon by EMEP and the Executive Body of CLRTAP in 2007: Methods and procedures for the technical review of air pollutant emission inventories reported under the Convention and its protocols ( ECE/EB.AIR/GE.1/2007/16 ).

§ Stage 1: An initial check of submissions for timeliness and completeness;

§ Stage 2: A synthesis and assessment of all national submissions with respect to consistency and comparability of data with recommendations for data quality improvement;

§ Stage 3: In-depth reviews of selected inventories, by pollutant, country or sector, as in the workplan agreed by the Executive Body.

If you have any comments concerning the results of the tests in this report, please contact the EMEP Centre on Emission Inventories and Projections (CEIP) by email at ‘emep.emissions@umweltbundesamt.at
within two weeks of your receiving this Status Report.


STAGE I REVIEW TESTS

This Stage 1 Status Report documents assesses the timeliness, completeness, and format of the submitted national inventories. It presents results of these initial automated tests to countries and supports the subsequent Stage II and Stage III review process. Stage I tests are:

§ 1a Timeliness

§ 1b Format of submission

§ 1c Completeness per sector for 2015 emissions

§ 1d Completeness per pollutant of your data in the WebDab database

Data included in tests:

§ Emissions reported under the Convention on LRTAP.

§ Emissions reported under the NECD Directive to the European Commission and European Environment Agency.


1a TIMELINESS

Date of submission of NECD : 15.2.2017 , received within deadline 15.02.2017 (Resubmission: 15.3.2017)

Date of submission of CLRTAP : 15.2.2017 , received within deadline 15.02.2017

Date of resubmission of CLRTAP : 15.3.2017 , received within deadline 15.03.2017

Informative Inventory Report (IIR) : 15.3.2017 , received within deadline 15.03.2017


1b FORMAT OF SUBMISSION

Parties are invited to check consistency of the format via RepDab (http://www.ceip.at/repdab_howtouse) before the submission of their inventory to the UNECE secretariat, the EMEP Centre on Emission Inventories and Projections (CEIP) and/or the European Commission/European Environment Agency. This section indicates whether the data submitted were in the Nomenclature for Reporting and the files were formatted as requested in the Guidelines for Estimating and Reporting Emission data. The current standard format for reporting is NFR14. Reporting templates can be downloaded from the CEIP website (http://www.ceip.at/reporting_instructions/annexes_to_guidelines).

NECD inventory submitted in format: NFR14 (Version 2014-1) for the years 1990 to 2015; Projections for the years 2020, 2025 and 2030

CLRTAP inventory submitted in format: NFR14 (Version 2014-1) for the years 1990 to 2015; Projections for the years 2020, 2025 and 2030; Grid and LPS data for 2015


1c COMPLETENESS PER SECTOR (YEAR 2015)

The tables below lists all sectors where 'Not Estimated (NE)' notation keys were reported for the year 2015. At the end of the table is a statistic of how many notation keys in general were reported per pollutant and a count of not estimated sectors per pollutant. If nothing at all is reported for a certain pollutant which is listed in the tables this is also indicated. For NECD you can see the sector completeness not only for 2015, but also for 2014 emission data.


CLRTAP (Completeness per sector for 2015):

SectorNOxNMVOCSOxNH3PM2.5PM10TSPBCCOPbCdHgAsCrCuNiSeZnDIOXPAHHCBPCB
                       
1A1b   NE                  
1A2a   NENENENENE NENENENENENENENENENENE  
1A2c   NE                  
1A2d   NE                  
1A2e   NE                  
1A2gviii   NE                  
1A3bi      NE    NENE      NE  
1A3bii      NE    NENE      NE  
1A3biii      NE    NENE      NE  
1A3biv      NE    NENE      NE  
1A3bvi      NENENENENENENENENENENE     
1A3bvii      NE NENENENENENENENENE     
1A3c           NE      NE   
1A3dii                  NE   
1A3ei    NENENENENENENENENENENENENENENENE  
1A3eiiNENENE NENENENENENENENENENENENENENENENE  
1A4aiiNENENE NENENENENENENENENENENENENENENENENENE
1A4bi                     NE
1A4ci                    NENE
1A4cii           NE      NE   
1A4ciii                  NE   
1A5b    NENENENE   NENE     NENE  
1B1a        NENENENENENENENENE     
1B1bNENENENENENENENENENENENENENENENENE NENE  
1B1cNENENENENENENENENENENENENENENENENENE    
1B2ai  NE              NE    
1B2aiv       NE         NE    
1B2av  NE              NE    
1B2b NENE              NE    
1B2c   NE   NE          NE   
1B2dNENENE NENENENENENENE  NENENENENENENENENE
2A1                  NENE  
2A2         NENE           
2A3       NE          NENE  
2A5a    NENENE               
2A5b NE  NENENE               
2A5c    NENENE               
2A6NE NE NENENENENENENENENENENENENENENENE  
2B1    NE                 
2B10a       NE NENENENENENENENENENENENENE
2B2    NE                 
2B7    NENENE               
2C1   NE   NE        NE     
2D3a    NENENENE              
2D3bNE NE    NE         NENENE  
2D3c NE  NENENENENENENE      NENENE  
2D3d    NENENENE              
2D3e    NENENENE              
2D3f    NENENENE              
2D3g       NENENENENENENENENENENENENENENE
2D3h    NENENENE              
2H1   NE   NE          NENE  
2H2    NENENE               
2INE NENENENENENE   NE NE        
2JNENENENENENENENE            NENE
2K        NENENENENENENENENE   NENE
2LNENENENE   NENENENENENENENENENENENENENENE
3B1a NE                    
3B1b NE                    
3Dc   NE                  
5B2NE                     
5C1bii   NE                  
5C1biv   NE                  
                       
11B    NENE NE NENENENENENENENENENENE  
1A3NENENENENENENENENENENENENENENENENENENENENENE
1A3ai(ii)    NENENENE              
1A3aii(ii)    NENENENE              
1A3di(i)                  NE   
                       
68 of 136 NFR14 Sectors listed                      
Count of overall notation keys8270100102868689110101104104114112104105104107106116114124126
Count of 'NE' notation keys1213141828263131151919242118171718182422910


NECD (Completeness per sector for 2015, 2010 and 2005):

2015

SectorNOxNMVOCSOxNH3PM2.5
      
1A1b   NE 
1A2a   NENE
1A2c   NE 
1A2d   NE 
1A2e   NE 
1A2gviii   NE 
1A3ei    NE
1A3eiiNENENE NE
1A4aiiNENENE NE
1A5b    NE
1B1bNENENENENE
1B1cNENENENENE
1B2ai  NE  
1B2av  NE  
1B2b NENE  
1B2c   NE 
1B2dNENENE NE
2A5a    NE
2A5b NE  NE
2A5c    NE
2A6NE NE NE
2B1    NE
2B2    NE
2B7    NE
2C1   NE 
2D3a    NE
2D3bNE NE  
2D3c NE  NE
2D3d    NE
2D3e    NE
2D3f    NE
2D3h    NE
2H1   NE 
2H2    NE
2INE NENENE
2JNENENENENE
2LNENENENE 
3B1a NE   
3B1b NE   
3Dc   NE 
5B2NE    
5C1bii   NE 
5C1biv   NE 
      
11B    NE
1A3NENENENENE
1A3ai(ii)    NE
1A3aii(ii)    NE
      
47 of 136 NFR14 Sectors listed     
Count of overall notation keys827010010286
Count of 'NE' notation keys1213141828

2010

SectorNOxNMVOCSOxNH3PM2.5
      
1A1b   NE 
1A2a   NENE
1A2c   NE 
1A2d   NE 
1A2e   NE 
1A2gviii   NE 
1A3ei    NE
1A3eiiNENENE NE
1A4aiiNENENE NE
1A5b    NE
1B1bNENENENENE
1B1cNENENENENE
1B2ai  NE  
1B2av  NE  
1B2b NENE  
1B2c   NE 
1B2dNENENE NE
2A5a    NE
2A5b NE  NE
2A5c    NE
2A6NE NE NE
2B1    NE
2B2    NE
2B7    NE
2C1   NE 
2D3a    NE
2D3bNE NE  
2D3c NE  NE
2D3d    NE
2D3e    NE
2D3f    NE
2D3h    NE
2H1   NE 
2H2    NE
2INE NENENE
2JNENENENENE
2LNENENENE 
3B1a NE   
3B1b NE   
3Dc   NE 
5B2NE    
5C1bii   NE 
5C1biv   NE 
      
11B    NE
1A3NENENENENE
1A3ai(ii)    NE
1A3aii(ii)    NE
      
47 of 136 NFR14 Sectors listed     
Count of overall notation keys837010010386
Count of 'NE' notation keys1213141828

2005

SectorNOxNMVOCSOxNH3PM2.5
      
1A1b   NE 
1A2aNENENENENE
1A2c   NE 
1A2d   NE 
1A2e   NE 
1A2gviii   NE 
1A3ei    NE
1A3eiiNENENE NE
1A4aiiNENENE NE
1A5b    NE
1B1bNENENENENE
1B1cNENENENENE
1B2ai  NE  
1B2av  NE  
1B2b NENE  
1B2c   NE 
1B2dNENENE NE
2A5a    NE
2A5b NE  NE
2A5c    NE
2A6NE NE NE
2B1    NE
2B2    NE
2B7    NE
2C1   NE 
2D3a    NE
2D3bNE NE  
2D3c NE  NE
2D3d    NE
2D3e    NE
2D3f    NE
2D3h    NE
2H1   NE 
2H2    NE
2INE NENENE
2JNENENENENE
2LNENENENE 
3B1a NE   
3B1b NE   
3Dc   NE 
5C1bii   NE 
5C1biv   NE 
      
11B    NE
1A3NENENENENE
1A3ai(ii)    NE
1A3aii(ii)    NE
      
46 of 136 NFR14 Sectors listed     
Count of overall notation keys837110110386
Count of 'NE' notation keys1214151828


1d COMPLETENESS PER POLLUTANT (entire time series)

The completeness of your data in the WebDab database has been evaluated on the basis of the criteria outlined in the 2014 Guidelines for Reporting Emission Data and Projections under the CLRTAP (ECE/EB.AIR/125):

All numbers in table are as a percentage of the total number of reporting template cells per component and time series. Flagging occurs when the number of cells containing a value or a notation key is less than 80% of the total number of cells, if there are more than 10% zeroes reported, if 'Not Estimated' is reported in cells and/or if the number of values reported is less than 10%. The completeness of CLRTAP NFR Sectors is divided in two sections: 1990 to 1999 and 2000 to 2015.


CLRTAP (Completeness of NFR Sectors from 2000 to 2015 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx39.30.022.28.920.99.00.00.0100.0
NMVOC47.50.019.410.013.010.00.00.0100.0
SOx26.30.022.410.332.09.00.00.0100.0
NH324.70.021.513.035.94.00.00.0100.0
PM2.537.10.019.921.014.08.00.00.0100.0
PM1037.10.019.919.016.08.00.00.0100.0
TSP35.10.019.923.016.07.00.00.0100.0
BC19.00.020.423.031.07.00.00.0100.0
CO25.90.019.411.335.48.00.00.0100.0
Pb24.00.019.214.036.07.00.00.0100.0
Cd24.00.019.214.036.07.00.00.0100.0
Hg16.10.019.218.039.67.00.00.0100.0
As18.10.019.216.040.67.00.00.0100.0
Cr24.00.019.213.036.67.00.00.0100.0
Cu23.10.019.213.039.65.00.00.0100.0
Ni23.60.019.813.037.67.00.00.0100.0
Se21.00.019.813.040.65.00.00.0100.0
Zn21.60.019.813.039.65.00.00.0100.0
DIOX15.10.019.218.041.66.00.00.0100.0
PAH16.00.019.916.041.66.00.00.0100.0
HCB8.00.019.07.062.64.00.00.0100.0
PCB7.00.019.07.062.94.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


CLRTAP (Completeness of NFR Sectors from 1990 to 1999 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx40.00.022.08.021.09.00.00.0100.0
NMVOC48.50.019.010.013.010.00.00.0100.0
SOx27.00.022.010.032.09.00.00.0100.0
NH325.10.021.013.936.04.00.00.0100.0
CO27.00.019.011.035.08.00.00.0100.0
Pb24.00.019.014.036.07.00.00.0100.0
Cd24.00.019.014.036.07.00.00.0100.0
Hg17.00.019.018.039.07.00.00.0100.0
As19.00.019.016.040.07.00.00.0100.0
Cr24.00.019.013.036.07.00.00.0100.0
Cu24.00.019.013.039.05.00.00.0100.0
Ni24.00.020.013.037.07.00.00.0100.0
Se21.00.020.013.040.05.00.00.0100.0
Zn22.00.020.013.039.05.00.00.0100.0
DIOX16.00.019.017.641.06.00.00.0100.0
PAH16.00.021.016.041.06.00.00.0100.0
HCB7.00.019.07.063.04.00.00.0100.0
PCB7.00.019.07.063.04.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


CLRTAP (Completeness of National Totals from 1990 to 2015 including NFR and SNAP):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx100.00.00.00.00.00.00.00.0100.0
NMVOC100.00.00.00.00.00.00.00.0100.0
SOx100.00.00.00.00.00.00.00.0100.0
NH3100.00.00.00.00.00.00.00.0100.0
PM2.5100.00.00.00.00.00.00.00.0100.0
PM10100.00.00.00.00.00.00.00.0100.0
TSP100.00.00.00.00.00.00.00.0100.0
BC100.00.00.00.00.00.00.00.0100.0
CO100.00.00.00.00.00.00.00.0100.0
Pb100.00.00.00.00.00.00.00.0100.0
Cd100.00.00.00.00.00.00.00.0100.0
Hg100.00.00.00.00.00.00.00.0100.0
As100.00.00.00.00.00.00.00.0100.0
Cr100.00.00.00.00.00.00.00.0100.0
Cu100.00.00.00.00.00.00.00.0100.0
Ni100.00.00.00.00.00.00.00.0100.0
Se100.00.00.00.00.00.00.00.0100.0
Zn100.00.00.00.00.00.00.00.0100.0
DIOX100.00.00.00.00.00.00.00.0100.0
PAH100.00.00.00.00.00.00.00.0100.0
HCB100.00.00.00.00.00.00.00.0100.0
PCB100.00.00.00.00.00.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences



-------------

NECD (Completeness of NFR Sectors from 2000 to 2015 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx39.30.022.28.920.99.00.00.0100.0
NMVOC47.50.019.410.013.010.00.00.0100.0
SOx26.30.022.410.332.09.00.00.0100.0
NH324.70.021.513.035.94.00.00.0100.0
PM2.537.10.019.921.014.08.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


NECD (Completeness of NFR Sectors from 1990 to 1999 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx40.00.022.08.021.09.00.00.0100.0
NMVOC48.50.019.010.013.010.00.00.0100.0
SOx27.00.022.010.032.09.00.00.0100.0
NH325.10.021.013.936.04.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


NECD (Completeness of National Totals from 1990 to 2015):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx100.00.00.00.00.00.00.00.0100.0
NMVOC100.00.00.00.00.00.00.00.0100.0
SOx100.00.00.00.00.00.00.00.0100.0
NH3100.00.00.00.00.00.00.00.0100.0
PM2.5100.00.00.00.00.00.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences