Technical Annual Status Report (Stage I) of CLRTAP Inventory Review for the former Yugoslav Republic of Macedonia

Generated by CEIP: 26 th April 2019

This status report was prepared by the EMEP Centre on Emission Inventories and Projections (CEIP) and European Topic Centre on Air and Climate Change (ETC/ACC). The Status Report provides information based on the initial checks of the CLRTAP inventories submitted in accordance with the reporting requirements of the UNECE Convention on Long-Range Transboundary Air Pollution (CLRTAP) and its protocols.


Review Process

The technical review of national inventories involves the checking and assessment of national data submissions with a view to improving the quality of emission data and associated information.

The annual review process is carried out in three stages in accordance with the review guidelines developed by the Task Force on Emission Inventories and Projections (TFEIP) and as agreed upon by EMEP and the Executive Body of CLRTAP in 2007: Methods and procedures for the technical review of air pollutant emission inventories reported under the Convention and its protocols ( ECE/EB.AIR/GE.1/2007/16 ).

§ Stage 1: An initial check of submissions for timeliness and completeness;

§ Stage 2: A synthesis and assessment of all national submissions with respect to consistency and comparability of data with recommendations for data quality improvement;

§ Stage 3: In-depth reviews of selected inventories, by pollutant, country or sector, as in the workplan agreed by the Executive Body.

If you have any comments concerning the results of the tests in this report, please contact the EMEP Centre on Emission Inventories and Projections (CEIP) by email at ‘emep.emissions@umweltbundesamt.at
within two weeks of your receiving this Status Report.


STAGE I REVIEW TESTS

This Stage 1 Status Report documents assesses the timeliness, completeness, and format of the submitted national inventories. It presents results of these initial automated tests to countries and supports the subsequent Stage II and Stage III review process. Stage I tests are:

§ 1a Timeliness

§ 1b Format of submission

§ 1c Completeness per sector for 2017 emissions

§ 1d Completeness per pollutant of your data in the WebDab database

Data included in tests:

§ Emissions reported under the Convention on LRTAP.


1a TIMELINESS

Date of submission of CLRTAP : 15.02.2019 , received within deadline 15.02.2019

Date of resubmission of CLRTAP : 16.04.2019 , received after deadline 15.03.2019


1b FORMAT OF SUBMISSION

Parties are invited to check consistency of the format via RepDab (http://www.ceip.at/repdab_howtouse) before the submission of their inventory to the UNECE secretariat, the EMEP Centre on Emission Inventories and Projections (CEIP) and/or the European Commission/European Environment Agency. This section indicates whether the data submitted were in the Nomenclature for Reporting and the files were formatted as requested in the Guidelines for Estimating and Reporting Emission data. The current standard format for reporting is NFR14. Reporting templates can be downloaded from the CEIP website (http://www.ceip.at/reporting_instructions/annexes_to_guidelines).

CLRTAP inventory submitted in format: NFR14 (Version 2014-1) for the years 1990 to 2017


1c COMPLETENESS PER SECTOR (YEAR 2017)

The tables below lists all sectors where 'Not Estimated (NE)' notation keys were reported for the year 2017. At the end of the table is a statistic of how many notation keys in general were reported per pollutant and a count of not estimated sectors per pollutant. If nothing at all is reported for a certain pollutant which is listed in the tables this is also indicated.


CLRTAP (Completeness per sector for 2017):

SectorNOxNMVOCSOxNH3PM2.5PM10TSPBCCOPbCdHgAsCrCuNiSeZnDIOXPAHHCBPCB
                       
1A1a                    NE 
1A1b   NE   NE              
1A1c                  NE   
1A2a   NE                  
1A2c   NE                NE 
1A2d   NE                  
1A2gvii  NE         NE         
1A2gviii   NE                  
1A3bii       NE              
1A3eiNENENENENENENENENENENENENENENENENENENENENENE
1A3eiiNENENENENENENENENENENENENENENENENENENENENENE
1A4ai                   NE  
1A4aiiNENENENENENENENENENENENENENENENENENENENENENE
1A4bii    NENE NE              
1A4ci   NE                  
1A4cii       NE              
1A4ciiiNENENENENENENENENENENENENENENENENENENENENENE
1A5aNENENENENENENENENENENENENENENENENENENENENENE
1B1b                  NE   
1B2dNENENE NENENENENENENE  NENENENENENENENENE
2A1                     NE
2B10aNENENENENENENENENENENENENENENENENENENENENENE
2B10bNENENENENENENENENENENENENENENENENENENENENENE
2C1   NE            NE   NE 
2C5           NE          
2C7b       NE              
2C7dNENENENENENENENENENENENENENENENENENENENENENE
2D3cNE        NENENE      NE   
2D3g   NE                  
2D3iNE NENE   NENENENENENENENENENENENE NENE
2G  NE      NE     NENENE  NENE
2H3NENENENENENENENENENENENENENENENENENENENENENE
2K           NE         NE
2LNENENENENENENENENENENENENENENENENENENENENENE
3B1b        NE             
3B3       NE NE            
3B4fNENE NENENENE               
3B4gi       NE              
3B4giii       NE              
3Da2a       NE              
3Da2bNE  NE                  
3Da3       NE              
3DcNENENENENENENENENENENENENENENENENENENENENENE
3Dd    NENENE               
3DeNENE NENENENE               
5B1NENENE NENENENENE             
5C1bi   NE         NENE NENE NE NE
5C1bii   NE            NENE NE  
5C1biv   NE                  
5C2   NE       NE   NE    NE 
5D1   NE                  
5D2 NE                    
6ANENENENENENENENENENENENENENENENENENENENENENE
                       
11CNENENENENENENENENENENENENENENENENENENENENENE
1A3NENENENENENENENENENENENENENENENENENENENENENE
1A5cNENENENENENENENENENENENENENENENENENENE   
6BNENENENENENENENENENENENENENENENENENENE   
                       
57 of 136 NFR14 Sectors listed                      
Count of overall notation keys9782109110848684113106115110121118112111113118113118119127123
Count of 'NE' notation keys23212133222221292021192118191920222121182120


1d COMPLETENESS PER POLLUTANT (entire time series)

The completeness of your data in the WebDab database has been evaluated on the basis of the criteria outlined in the 2014 Guidelines for Reporting Emission Data and Projections under the CLRTAP (ECE/EB.AIR/125):

All numbers in table are as a percentage of the total number of reporting template cells per component and time series. Flagging occurs when the number of cells containing a value or a notation key is less than 80% of the total number of cells, if there are more than 10% zeroes reported, if 'Not Estimated' is reported in cells and/or if the number of values reported is less than 10%. The completeness of CLRTAP NFR Sectors is divided in two sections: 1990 to 1999 and 2000 to 2017.


CLRTAP (Completeness of NFR Sectors from 2000 to 2017 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx29.70.023.116.927.03.80.00.0100.0
NMVOC40.80.023.115.017.33.80.00.0100.0
SOx19.30.023.115.939.31.80.00.0100.0
NH319.70.019.924.135.31.00.00.0100.0
PM2.536.50.022.918.520.01.80.00.0100.0
PM1034.70.022.918.521.01.80.00.0100.0
TSP38.60.023.916.120.01.80.00.0100.0
BC16.10.020.823.439.11.00.00.0100.0
CO22.70.023.114.938.31.00.00.0100.0
Pb16.20.023.915.844.01.00.00.0100.0
Cd19.20.022.913.942.01.00.00.0100.0
Hg12.80.022.915.248.61.00.00.0100.0
As13.70.023.213.548.61.00.00.0100.0
Cr18.80.022.113.044.31.00.00.0100.0
Cu18.90.022.113.744.01.00.00.0100.0
Ni17.10.022.914.744.01.00.00.0100.0
Se15.60.022.115.146.41.00.00.0100.0
Zn17.20.021.315.044.81.00.00.0100.0
DIOX13.90.022.915.946.91.00.00.0100.0
PAH12.90.021.213.052.01.00.00.0100.0
HCB7.30.023.414.154.31.00.00.0100.0
PCB9.40.022.414.953.01.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


CLRTAP (Completeness of NFR Sectors from 1990 to 1999 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx27.90.022.118.028.04.00.00.0100.0
NMVOC40.80.022.116.018.14.00.00.0100.0
SOx18.00.022.116.940.92.00.00.0100.0
NH316.90.019.127.135.11.00.00.0100.0
CO21.00.022.116.039.11.00.00.0100.0
Pb16.30.023.016.044.01.00.00.0100.0
Cd19.20.022.114.042.71.00.00.0100.0
Hg13.10.022.117.446.91.00.00.0100.0
As13.60.022.116.347.01.00.00.0100.0
Cr18.20.021.113.045.71.00.00.0100.0
Cu18.20.021.114.044.71.00.00.0100.0
Ni16.20.022.115.044.71.00.00.0100.0
Se16.00.021.115.046.71.00.00.0100.0
Zn18.20.021.015.044.71.00.00.0100.0
DIOX14.10.022.016.047.11.00.00.0100.0
PAH12.00.021.013.052.91.00.00.0100.0
HCB7.00.122.414.055.81.00.00.0100.0
PCB9.90.121.115.053.01.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


CLRTAP (Completeness of National Totals from 1990 to 2017 including NFR and SNAP):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx100.00.00.00.00.00.00.00.0100.0
NMVOC100.00.00.00.00.00.00.00.0100.0
SOx100.00.00.00.00.00.00.00.0100.0
NH3100.00.00.00.00.00.00.00.0100.0
PM2.5100.00.00.00.00.00.00.00.0100.0
PM10100.00.00.00.00.00.00.00.0100.0
TSP100.00.00.00.00.00.00.00.0100.0
BC100.00.00.00.00.00.00.00.0100.0
CO100.00.00.00.00.00.00.00.0100.0
Pb100.00.00.00.00.00.00.00.0100.0
Cd100.00.00.00.00.00.00.00.0100.0
Hg100.00.00.00.00.00.00.00.0100.0
As100.00.00.00.00.00.00.00.0100.0
Cr100.00.00.00.00.00.00.00.0100.0
Cu100.00.00.00.00.00.00.00.0100.0
Ni100.00.00.00.00.00.00.00.0100.0
Se100.00.00.00.00.00.00.00.0100.0
Zn100.00.00.00.00.00.00.00.0100.0
DIOX100.00.00.00.00.00.00.00.0100.0
PAH100.00.00.00.00.00.00.00.0100.0
HCB100.00.00.00.00.00.00.00.0100.0
PCB100.00.00.00.00.00.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences