Technical Annual Status Report (Stage I) of CLRTAP and NECD Inventory Review for Italy

Generated by CEIP: 26 th April 2019

This status report was prepared by the EMEP Centre on Emission Inventories and Projections (CEIP) and European Topic Centre on Air and Climate Change (ETC/ACC). The Status Report provides information based on the initial checks of the CLRTAP and NECD inventories submitted in accordance with the reporting requirements of the UNECE Convention on Long-Range Transboundary Air Pollution (CLRTAP) and its protocols, and for EU Member States the Directive 2001/81/EC of the European Parliament and of the Council on national emission ceilings for certain atmospheric pollutants (NECD).


Review Process

The technical review of national inventories involves the checking and assessment of national data submissions with a view to improving the quality of emission data and associated information.

The annual review process is carried out in three stages in accordance with the review guidelines developed by the Task Force on Emission Inventories and Projections (TFEIP) and as agreed upon by EMEP and the Executive Body of CLRTAP in 2007: Methods and procedures for the technical review of air pollutant emission inventories reported under the Convention and its protocols ( ECE/EB.AIR/GE.1/2007/16 ).

§ Stage 1: An initial check of submissions for timeliness and completeness;

§ Stage 2: A synthesis and assessment of all national submissions with respect to consistency and comparability of data with recommendations for data quality improvement;

§ Stage 3: In-depth reviews of selected inventories, by pollutant, country or sector, as in the workplan agreed by the Executive Body.

If you have any comments concerning the results of the tests in this report, please contact the EMEP Centre on Emission Inventories and Projections (CEIP) by email at ‘emep.emissions@umweltbundesamt.at
within two weeks of your receiving this Status Report.


STAGE I REVIEW TESTS

This Stage 1 Status Report documents assesses the timeliness, completeness, and format of the submitted national inventories. It presents results of these initial automated tests to countries and supports the subsequent Stage II and Stage III review process. Stage I tests are:

§ 1a Timeliness

§ 1b Format of submission

§ 1c Completeness per sector for 2017 emissions

§ 1d Completeness per pollutant of your data in the WebDab database

Data included in tests:

§ Emissions reported under the Convention on LRTAP.

§ Emissions reported under the NECD Directive to the European Commission and European Environment Agency.


1a TIMELINESS

Date of submission of NECD : 01.03.2019 , received after deadline 15.02.2019 (Resubmission: 19.04.2019)

Date of submission of CLRTAP : 28.02.2019 , received after deadline 15.02.2019

Date of resubmission of CLRTAP : 19.04.2019 , received after deadline 15.03.2019


1b FORMAT OF SUBMISSION

Parties are invited to check consistency of the format via RepDab (http://www.ceip.at/repdab_howtouse) before the submission of their inventory to the UNECE secretariat, the EMEP Centre on Emission Inventories and Projections (CEIP) and/or the European Commission/European Environment Agency. This section indicates whether the data submitted were in the Nomenclature for Reporting and the files were formatted as requested in the Guidelines for Estimating and Reporting Emission data. The current standard format for reporting is NFR14. Reporting templates can be downloaded from the CEIP website (http://www.ceip.at/reporting_instructions/annexes_to_guidelines).

NECD inventory submitted in format: NFR14 (Version 2014-1) for the years 1990 to 2017; Projections for the years 2020, 2025 and 2030

CLRTAP inventory submitted in format: NFR14 (Version 2014-1) for the years 1990 to 2017; Projections for the years 2020, 2025 and 2030


1c COMPLETENESS PER SECTOR (YEAR 2017)

The tables below lists all sectors where 'Not Estimated (NE)' notation keys were reported for the year 2017. At the end of the table is a statistic of how many notation keys in general were reported per pollutant and a count of not estimated sectors per pollutant. If nothing at all is reported for a certain pollutant which is listed in the tables this is also indicated. For NECD you can see the sector completeness not only for 2017, but also for 2010 and 2005 emission data.


CLRTAP (Completeness per sector for 2017):

SectorNOxNMVOCSOxNH3PM2.5PM10TSPBCCOPbCdHgAsCrCuNiSeZnDIOXPAHHCBPCB
                       
1A3ai(i)   NE                  
1A3aii(i)   NE                  
1A3bv                  NENE NE
1A3bvi       NE          NENE NE
1A3bvii       NE NENENENENENENENENENENE NE
1A3ei   NE                  
2A5a    NENENENE              
2A5b    NENENENE              
2G    NENENENE              
3Da4NE  NE                  
3DbNE  NE                  
                       
1A5cNENENENENENENENENENENENENENENENENENENENENENE
                       
12 of 136 NFR14 Sectors listed                      
Count of overall notation keys7257898470696987931039711011010110010110510411298121119
Count of 'NE' notation keys3116444612222222224414


NECD (Completeness per sector for 2017, 2010 and 2005):

2017

SectorNOxNMVOCSOxNH3
     
1A3ai(i)   NE
1A3aii(i)   NE
1A3ei   NE
3Da4NE  NE
3DbNE  NE
     
1A5cNENENENE
     
6 of 136 NFR14 Sectors listed    
Count of overall notation keys72578984
Count of 'NE' notation keys3116

2010

SectorNOxNMVOCSOxNH3
     
1A3ai(i)   NE
1A3aii(i)   NE
1A3ei   NE
3Da4NE  NE
3DbNE  NE
     
1A5cNENENENE
     
6 of 136 NFR14 Sectors listed    
Count of overall notation keys69548684
Count of 'NE' notation keys3116

2005

SectorNOxNMVOCSOxNH3
     
1A3ai(i)   NE
1A3aii(i)   NE
1A3ei   NE
3Da4NE  NE
3DbNE  NE
     
1A5cNENENENE
     
6 of 136 NFR14 Sectors listed    
Count of overall notation keys67538484
Count of 'NE' notation keys3116


1d COMPLETENESS PER POLLUTANT (entire time series)

The completeness of your data in the WebDab database has been evaluated on the basis of the criteria outlined in the 2014 Guidelines for Reporting Emission Data and Projections under the CLRTAP (ECE/EB.AIR/125):

All numbers in table are as a percentage of the total number of reporting template cells per component and time series. Flagging occurs when the number of cells containing a value or a notation key is less than 80% of the total number of cells, if there are more than 10% zeroes reported, if 'Not Estimated' is reported in cells and/or if the number of values reported is less than 10%. The completeness of CLRTAP NFR Sectors is divided in two sections: 1990 to 1999 and 2000 to 2017.


CLRTAP (Completeness of NFR Sectors from 2000 to 2017 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx49.00.010.42.035.63.00.00.0100.0
NMVOC60.10.010.21.027.12.00.00.0100.0
SOx36.60.010.41.048.14.00.00.0100.0
NH338.10.010.24.044.73.00.00.0100.0
PM2.550.70.09.43.031.16.00.00.0100.0
PM1051.50.09.43.030.36.00.00.0100.0
TSP51.50.09.43.030.36.00.00.0100.0
BC38.20.08.64.043.35.00.00.0100.0
CO33.00.010.41.054.61.00.00.0100.0
Pb25.60.010.21.059.93.00.00.0100.0
Cd30.20.010.21.055.63.00.00.0100.0
Hg20.50.010.41.065.42.00.00.0100.0
As20.60.010.41.066.31.00.00.0100.0
Cr27.30.010.41.059.31.00.00.0100.0
Cu27.40.010.21.059.31.00.00.0100.0
Ni28.00.010.41.059.01.00.00.0100.0
Se24.30.010.41.062.31.00.00.0100.0
Zn25.90.010.21.061.21.00.00.0100.0
DIOX18.50.010.43.067.01.00.00.0100.0
PAH28.90.010.23.056.61.00.00.0100.0
HCB11.90.010.21.076.01.00.00.0100.0
PCB13.70.010.43.070.82.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


CLRTAP (Completeness of NFR Sectors from 1990 to 1999 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx50.00.08.62.036.03.00.00.0100.0
NMVOC61.00.08.61.027.02.00.00.0100.0
SOx38.00.08.61.048.44.00.00.0100.0
NH335.90.08.64.048.03.00.00.0100.0
CO34.00.08.61.055.41.00.00.0100.0
Pb30.00.08.61.057.43.00.00.0100.0
Cd31.00.08.61.056.03.00.00.0100.0
Hg21.00.08.61.066.42.00.00.0100.0
As21.00.08.61.067.01.00.00.0100.0
Cr28.00.08.61.060.41.00.00.0100.0
Cu28.00.08.61.060.41.00.00.0100.0
Ni29.00.08.61.059.41.00.00.0100.0
Se25.00.08.61.063.41.00.00.0100.0
Zn27.00.08.61.061.41.00.00.0100.0
DIOX19.00.08.63.067.41.00.00.0100.0
PAH30.00.08.63.057.41.00.00.0100.0
HCB12.00.08.61.077.41.00.00.0100.0
PCB14.00.08.63.072.42.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


CLRTAP (Completeness of National Totals from 1990 to 2017 including NFR and SNAP):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx100.00.00.00.00.00.00.00.0100.0
NMVOC100.00.00.00.00.00.00.00.0100.0
SOx100.00.00.00.00.00.00.00.0100.0
NH3100.00.00.00.00.00.00.00.0100.0
PM2.5100.00.00.00.00.00.00.00.0100.0
PM10100.00.00.00.00.00.00.00.0100.0
TSP100.00.00.00.00.00.00.00.0100.0
BC100.00.00.00.00.00.00.00.0100.0
CO100.00.00.00.00.00.00.00.0100.0
Pb100.00.00.00.00.00.00.00.0100.0
Cd100.00.00.00.00.00.00.00.0100.0
Hg100.00.00.00.00.00.00.00.0100.0
As100.00.00.00.00.00.00.00.0100.0
Cr100.00.00.00.00.00.00.00.0100.0
Cu100.00.00.00.00.00.00.00.0100.0
Ni100.00.00.00.00.00.00.00.0100.0
Se100.00.00.00.00.00.00.00.0100.0
Zn100.00.00.00.00.00.00.00.0100.0
DIOX100.00.00.00.00.00.00.00.0100.0
PAH100.00.00.00.00.00.00.00.0100.0
HCB100.00.00.00.00.00.00.00.0100.0
PCB100.00.00.00.00.00.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences



-------------

NECD (Completeness of NFR Sectors from 2000 to 2017 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx49.00.010.42.035.63.00.00.0100.0
NMVOC60.10.010.21.027.12.00.00.0100.0
SOx36.60.010.41.048.14.00.00.0100.0
NH338.10.010.24.044.73.00.00.0100.0
PM2.550.70.09.43.031.16.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


NECD (Completeness of NFR Sectors from 1990 to 1999 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx50.00.08.62.036.03.00.00.0100.0
NMVOC61.00.08.61.027.02.00.00.0100.0
SOx38.00.08.61.048.44.00.00.0100.0
NH335.90.08.64.048.03.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


NECD (Completeness of National Totals from 1990 to 2017):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx100.00.00.00.00.00.00.00.0100.0
NMVOC100.00.00.00.00.00.00.00.0100.0
SOx100.00.00.00.00.00.00.00.0100.0
NH3100.00.00.00.00.00.00.00.0100.0
PM2.5100.00.00.00.00.00.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences