Technical Annual Status Report (Stage I) of CLRTAP and NECD Inventory Review for Bulgaria

Generated by CEIP: 6 th May 2021

This status report was prepared by the EMEP Centre on Emission Inventories and Projections (CEIP) and European Topic Centre on Air and Climate Change (ETC/ACC). The Status Report provides information based on the initial checks of the CLRTAP and NECD inventories submitted in accordance with the reporting requirements of the UNECE Convention on Long-Range Transboundary Air Pollution (CLRTAP) and its protocols, and for EU Member States the Directive 2001/81/EC of the European Parliament and of the Council on national emission ceilings for certain atmospheric pollutants (NECD).


Review Process

The technical review of national inventories involves the checking and assessment of national data submissions with a view to improving the quality of emission data and associated information.

The annual review process is carried out in three stages in accordance with the review guidelines developed by the Task Force on Emission Inventories and Projections (TFEIP) and as agreed upon by EMEP and the Executive Body of CLRTAP in 2007: Methods and procedures for the technical review of air pollutant emission inventories reported under the Convention and its protocols ( ECE/EB.AIR/GE.1/2007/16 ).

§ Stage 1: An initial check of submissions for timeliness and completeness;

§ Stage 2: A synthesis and assessment of all national submissions with respect to consistency and comparability of data with recommendations for data quality improvement;

§ Stage 3: In-depth reviews of selected inventories, by pollutant, country or sector, as in the workplan agreed by the Executive Body.

If you have any comments concerning the results of the tests in this report, please contact the EMEP Centre on Emission Inventories and Projections (CEIP) by email at ‘emep.emissions@umweltbundesamt.at
within two weeks of your receiving this Status Report.


STAGE I REVIEW TESTS

This Stage 1 Status Report documents assesses the timeliness, completeness, and format of the submitted national inventories. It presents results of these initial automated tests to countries and supports the subsequent Stage II and Stage III review process. Stage I tests are:

§ 1a Timeliness

§ 1b Format of submission

§ 1c Completeness per sector for 2019 emissions

§ 1d Completeness per pollutant of your data in the WebDab database

Data included in tests:

§ Emissions reported under the Convention on LRTAP.

§ Emissions reported under the NECD Directive to the European Commission and European Environment Agency.


1a TIMELINESS

Date of submission of NECD : 12.02.2021 , received within deadline 15.02.2021 (Resubmission: 15.03.2021)

Date of submission of CLRTAP : 12.02.2021 , received within deadline 15.02.2021

Date of resubmission of CLRTAP : 21.04.2021 , received after deadline 15.03.2021


1b FORMAT OF SUBMISSION

Parties are invited to check consistency of the format via RepDab (http://www.ceip.at/repdab_howtouse) before the submission of their inventory to the UNECE secretariat, the EMEP Centre on Emission Inventories and Projections (CEIP) and/or the European Commission/European Environment Agency. This section indicates whether the data submitted were in the Nomenclature for Reporting and the files were formatted as requested in the Guidelines for Estimating and Reporting Emission data. The current standard format for reporting is NFR19. Reporting templates can be downloaded from the CEIP website (http://www.ceip.at/reporting_instructions/annexes_to_guidelines).

NECD inventory submitted in format: NFR19 (Version 2019-1) for the years 1990 to 2019; Projections for the years 2020, 2025 and 2030; Gridded emissions and LPS for the year 2019

CLRTAP inventory submitted in format: NFR19 (Version 2019-1) for the years 1990 to 2019; Projections for the years 2020, 2025 and 2030; Gridded emissions and LPS for the year 2019


1c COMPLETENESS PER SECTOR (YEAR 2019)

The tables below lists all sectors where 'Not Estimated (NE)' notation keys were reported for the year 2019. At the end of the table is a statistic of how many notation keys in general were reported per pollutant and a count of not estimated sectors per pollutant. If nothing at all is reported for a certain pollutant which is listed in the tables this is also indicated. For NECD you can see the sector completeness not only for 2019, but also for 2010 and 2005 emission data.


CLRTAP (Completeness per sector for 2019):

SectorNOxNMVOCSOxNH3PM2.5PM10TSPBCCOPbCdHgAsCrCuNiSeZnDIOXPAHHCBPCB
                       
1A3ai(i)      NENE  NENENENENENENENENENE  
1A3aii(i)   NE NENENE  NENENENENENENENENENE  
1A3bvi         NENENENENENENENENENENENENE
1A3bvii         NENENENENENENENENENENENENE
1A3eiiNENENENENENENENENENENENENENENENENENENENENENE
1A5bNENENENENENENENENENENENENENENENENENENENENENE
2A5a    NENENE               
2A5b    NENENE               
2A5c    NENENE               
2C7dNENENENENENENENENENENENENENENENENENENENENENE
2D3a    NE                 
2D3d    NE      NE          
2D3e    NE      NE          
2D3f    NE      NE          
2D3g    NE      NE          
2D3h    NE      NE          
2G                NE   NENE
2INENENENENENENENENENENENENENENENENENENENENENE
2JNENENENENENENENENENENENENENENENENENENENENENE
2LNENENENENENENENENENENENENENENENENENENENENENE
5C1bi   NE                  
                       
11CNENE NENENENENE              
1A3ai(ii)      NENE  NENENENENENENENENENE  
1A3aii(ii)   NE  NENE NENENENENENENENENENENE  
                       
24 of 135 Sectors listed                      
Count of overall notation keys8773100100869085123100111107111111108109108113111113112123119
Count of 'NE' notation keys7761016111411691217121212121312121299


NECD (Completeness per sector for 2019, 2010 and 2005):

2019

SectorNOxNMVOCSOxNH3PM2.5
      
1A3aii(i)   NE 
1A3eiiNENENENENE
1A5bNENENENENE
2A5a    NE
2A5b    NE
2A5c    NE
2C7dNENENENENE
2D3a    NE
2D3d    NE
2D3e    NE
2D3f    NE
2D3g    NE
2D3h    NE
2INENENENENE
2JNENENENENE
2LNENENENENE
5C1bi   NE 
      
11CNENE NENE
1A3aii(ii)   NE 
      
19 of 135 Sectors listed     
Count of overall notation keys877310010086
Count of 'NE' notation keys7761016

2010

SectorNOxNMVOCSOxNH3PM2.5
      
1A3aii(i)   NE 
1A3eiiNENENENENE
1A4biiNENENENENE
1A5bNENENENENE
2A5a    NE
2A5b    NE
2A5c    NE
2B5    NE
2C7dNENENENENE
2D3a    NE
2D3d    NE
2D3e    NE
2D3f    NE
2D3g    NE
2D3h    NE
2INENENENENE
2JNENENENENE
2LNENENENENE
3B4h   NE 
5C1bi   NE 
      
11CNENE NENE
1A3aii(ii)   NE 
      
22 of 135 Sectors listed     
Count of overall notation keys86729710586
Count of 'NE' notation keys8871218

2005

SectorNOxNMVOCSOxNH3PM2.5
      
1A3aii(i)   NE 
1A3eiiNENENENENE
1A5bNENENENENE
2A5a    NE
2A5b    NE
2A5c    NE
2B5    NE
2C7dNENENENENE
2D3a    NE
2D3d    NE
2D3e    NE
2D3f    NE
2D3g    NE
2D3h    NE
2INENENENENE
2JNENENENENE
2LNENENENENE
3B4h NENENE 
5C1bi   NE 
      
11CNENE NENE
1A3aii(ii)   NE 
      
21 of 135 Sectors listed     
Count of overall notation keys87739710487
Count of 'NE' notation keys7871117


1d COMPLETENESS PER POLLUTANT (entire time series)

The completeness of your data in the WebDab database has been evaluated on the basis of the criteria outlined in the 2014 Guidelines for Reporting Emission Data and Projections under the CLRTAP (ECE/EB.AIR/125):

All numbers in table are as a percentage of the total number of reporting template cells per component and time series. Flagging occurs when the number of cells containing a value or a notation key is less than 80% of the total number of cells, if there are more than 10% zeroes reported, if 'Not Estimated' is reported in cells and/or if the number of values reported is less than 10%. The completeness of CLRTAP NFR Sectors is divided in two sections: 1990 to 1999 and 2000 to 2019.


CLRTAP (Completeness of NFR Sectors from 2000 to 2019 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx36.90.016.55.334.57.80.00.0100.0
NMVOC47.90.015.35.723.28.80.00.0100.0
SOx27.81.015.35.743.47.80.00.0100.0
NH324.40.116.57.243.28.80.00.0100.0
PM2.537.00.015.312.927.47.80.00.0100.0
PM1035.30.015.38.932.87.80.00.0100.0
TSP41.20.115.39.027.37.80.00.0100.0
BC9.90.015.215.651.27.80.00.0100.0
CO27.90.015.35.343.97.80.00.0100.0
Pb19.80.015.36.051.47.80.00.0100.0
Cd23.30.115.37.346.27.80.00.0100.0
Hg18.41.015.311.345.87.80.00.0100.0
As19.31.015.37.349.87.80.00.0100.0
Cr22.30.115.37.348.26.80.00.0100.0
Cu21.20.015.37.349.26.80.00.0100.0
Ni22.10.115.37.347.47.80.00.0100.0
Se19.10.615.38.350.16.80.00.0100.0
Zn19.80.015.37.350.46.80.00.0100.0
DIOX17.40.014.38.351.58.80.00.0100.0
PAH16.90.115.38.352.07.80.00.0100.0
HCB10.40.114.77.360.07.50.00.0100.0
PCB10.30.015.37.260.36.80.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


CLRTAP (Completeness of NFR Sectors from 1990 to 1999 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx36.01.115.34.735.77.10.00.0100.0
NMVOC46.70.014.06.025.38.20.00.0100.0
SOx27.31.014.06.045.37.20.00.0100.0
NH324.00.016.27.044.68.20.00.0100.0
CO27.70.014.05.046.17.20.00.0100.0
Pb20.00.014.06.053.67.20.00.0100.0
Cd23.80.014.07.047.87.20.00.0100.0
Hg18.41.014.011.047.47.20.00.0100.0
As19.21.014.07.051.67.20.00.0100.0
Cr22.20.014.07.050.06.20.00.0100.0
Cu21.20.014.07.050.66.20.00.0100.0
Ni23.00.014.07.048.87.20.00.0100.0
Se19.20.014.08.052.56.30.00.0100.0
Zn20.20.014.07.051.76.30.00.0100.0
DIOX17.20.013.08.053.68.20.00.0100.0
PAH16.90.014.08.054.07.20.00.0100.0
HCB11.00.013.07.061.86.20.00.0100.0
PCB9.00.014.07.062.86.20.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


CLRTAP (Completeness of National Totals from 1990 to 2019 including NFR and SNAP):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx100.00.00.00.00.00.00.00.0100.0
NMVOC100.00.00.00.00.00.00.00.0100.0
SOx100.00.00.00.00.00.00.00.0100.0
NH3100.00.00.00.00.00.00.00.0100.0
PM2.5100.00.00.00.00.00.00.00.0100.0
PM10100.00.00.00.00.00.00.00.0100.0
TSP100.00.00.00.00.00.00.00.0100.0
BC100.00.00.00.00.00.00.00.0100.0
CO100.00.00.00.00.00.00.00.0100.0
Pb100.00.00.00.00.00.00.00.0100.0
Cd100.00.00.00.00.00.00.00.0100.0
Hg100.00.00.00.00.00.00.00.0100.0
As100.00.00.00.00.00.00.00.0100.0
Cr100.00.00.00.00.00.00.00.0100.0
Cu100.00.00.00.00.00.00.00.0100.0
Ni100.00.00.00.00.00.00.00.0100.0
Se100.00.00.00.00.00.00.00.0100.0
Zn100.00.00.00.00.00.00.00.0100.0
DIOX100.00.00.00.00.00.00.00.0100.0
PAH100.00.00.00.00.00.00.00.0100.0
HCB100.00.00.00.00.00.00.00.0100.0
PCB100.00.00.00.00.00.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences



-------------

NECD (Completeness of NFR Sectors from 2000 to 2019 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx36.90.016.55.334.57.80.00.0100.0
NMVOC47.90.015.35.723.28.80.00.0100.0
SOx27.81.015.35.743.47.80.00.0100.0
NH324.40.116.57.243.28.80.00.0100.0
PM2.537.00.015.312.927.47.80.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


NECD (Completeness of NFR Sectors from 1990 to 1999 without National Totals):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx36.01.115.34.735.77.10.00.0100.0
NMVOC46.70.014.06.025.38.20.00.0100.0
SOx27.31.014.06.045.37.20.00.0100.0
NH324.00.016.27.044.68.20.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences


NECD (Completeness of National Totals from 1990 to 2019):

Component% Value% 0% NO% NE% NA% IE% C% NR% All
NOx100.00.00.00.00.00.00.00.0100.0
NMVOC100.00.00.00.00.00.00.00.0100.0
SOx100.00.00.00.00.00.00.00.0100.0
NH3100.00.00.00.00.00.00.00.0100.0
PM2.5100.00.00.00.00.00.00.00.0100.0

"Value" – the cell contains a number > 0.005;
"0" – the cell contains 0 or a number < 0.005;
"NO", "NE", "NA", "IE", "C" and "NR" are notation keys as defined in Reporting Guidelines and NFR;
In certain cases the total percentage value may not be exactly the sum of the other columns because of rounding differences